Product introduction
KL88 series ultrasonic flowmeter/calorimeter is a kind of universal time-difference ultrasonic flow measuring instrument based on similar foreign products, which is widely used for uninterrupted measurement of clean and uniform liquid flow and heat in industrial environment. With strong adaptability, low power consumption, high reliability, anti-interference and optimized intelligent signal adaptive processing ability, no circuit adjustment, simple and convenient operation. The good circuit design concept and the selection of high-quality devices have gradually replaced the early similar products and become the most widely used flow metering instruments in China.
Product advantage
The hand-held, external clamped, ultrasonic flowmeter realizes the non-contact measurement of liquid flow, and the sensor is installed on the outer wall of the pipeline to complete the measurement of flow. It has the characteristics of small volume, easy to carry and accurate measurement.
The plug-in ultrasonic flowmeter only needs to be installed in the pipeline under test. The plug-in sensor can be installed in the field without stopping water by using the transmission machine, and the measurement is more stable and reliable because the sensor is in direct contact with the fluid.
The tubular ultrasonic flowmeter has the advantages of simple installation, low initial measurable flow, high measurement accuracy and no pressure loss.
Technical performance
Caliber/Accuracy: DN15 ~ DN6000: better than ±1%
Display: Dot matrix back north light LCD, support Chinese, English, Italian, French four languages
Measurement medium: a single uniform liquid that can conduct ultrasonic waves
Flow rate measurement range: ± 0.1m /s ~ ±10m/s positive and negative direction can be measured
Current output: 4-20mA current output, impedance 0-1K
Pulse output: pulse output (pulse width 6 ~ 10000ms, factory default 200ms)
Alarm output: one relay alarm output with photoelectric isolation
Open collector: contact capacity Vmax=36VDC Imax=250mA
Communication interface: With isolated RS485 serial interface, support MODBUS-RTU collaborator
Turbidity: less than 10000ppm and small bubble content
Power supply: AC power supply: U(m)=220VAC (+10%/-15%) I(m)≤0.1A Frequency: 45 to 63HZ
Dc 24V switching power supply: 18VDC to 32VDC
Dissipation power: less than 15W
Electrical interface: M20×1.5
Ambient temperature: -20℃ ~ 60℃
Relative humidity: 5% ~ 80%RH
Medium maximum temperature: -30℃ ~ 160℃
Housing material: flame retardant ABS
Pipe material: steel, stainless steel, cast iron, aluminum, copper, glass fiber reinforced plastic, PVC and other dense pipes are allowed to be lined.
Install straight pipe section: at least 10D before and 5D after. Distance from pump outlet is more than 30D.(D is pipe diameter)
Protection level: Host :IP30; Sensor :IP67\IP68
Main use
Ultrasonic flowmeters can be used to measure: water, sea water, industrial sewage, acid lye, alcohol, beer, various oils and other single uniform liquid that can conduct ultrasonic waves.